The Reason of Diesel Generating Set No Power output and 9 solutions

Update:2017-06-06 16:39Author:admin
The Reason of Diesel Generating Set No Power output and 9 solutions: When diesel generator fails to generate electricity, we should be aware of the reasons so that we can better solve the problem.The diesel generator sets manufacturers Hua
The Reason of Diesel Generating Set No Power output and 9 solutions:
 
When diesel generator fails to generate electricity, we should be aware of the reasons so that we can better solve the problem.The diesel generator sets manufacturers  Huaquan Power will tell you that diesel generator sets power generation failure and 9 major solutions:
 
(1) often lost demagnetization after off the generator, is due to the magnetic pole of the material which close the soft steel, remain small, after stopping the magnetic field which there is no current that the magnetic field disappeared.
 
(2) the magnetic pole of the generator is lost.
 
(3) damage to the excitation circuit components or lines are broken,short circuit or ground phenomenon.
 
(4) Exciter brush and commutator bad contact or brush frame pressure is insufficient.
 
(5) field winding wiring error, the opposite polarity.
 
(6) generator brush and slip ring bad contact, or brush pressure is insufficient.
 
(7) generator stator windings or rotor windings.
(8) generator lead wire wiring loose or switch contact bad.
 
(9) fuse blown
 
9 solutions,
 
(1) spare battery,before working,psl fillthe  magnetization.
  
(2) in the winding than the rated current into the DC (time is very short) to magnetize, the specific current determined by the test.
 
(3) replace the damaged components, repair fault lines.
 
(4) clear the contact surface of the scale, adjust the brush pressure, fastening brush holder.
 
(5) correct the wiring, press the exact polarity of the magnetization.
 
(6) to the contact surface scale, grinding brush, adjust the brush brush pressure, so that brush and slip ring in close contact.
 
(7) Check and repair the circuit breaker.
 
(8) Connect the connector or repair the contact area.
 
(9) to identify the cause of the fuse, determine the generator itself and the line is normal, replace the specified fuse.    
 
--------------------------------------------------------------------------------------
TEL: +86 536 8185702
Mob£º+86 15905360231
SKYPE: huaquanpower
Wechat/whatApp:+86 15905360231
EMAIL: hqpower@huaquanpower.com
ADD: Xinzheng Industrial Park£¬Qingyuan West Street£¬Weifang Economic Development Zone,Shandong Province,China
--------------------------------------------------------------------------------------
 

Source:http://www.china-quan.com/en/News/Company_News/545.html

Copyright Shandong Huaquan Power Co.,Ltd All rights reserved.